126KV Outdoor high-voltage SF6 ceramic column circuit breaker

126KV Outdoor high-voltage SF6 ceramic column circuit breaker

126KV Outdoor high-voltage SF6 ceramic column circuit breaker is a high-voltage sulfur hexafluoride device used in outdoor electrical systems operating at 126kV. It is designed to manage and safeguard power transmission and transformation networks. This breaker can serve as a switch and disconnection unit when needed. The breaker's innovative arc extinguishing technique involves thermal expansion and auxiliary blowing, and it incorporates a CTB-1 operating mechanism. It complies with the GB1984-2003 standard for AC High Voltage Circuit Breakers and ful specifications of the IEC62271-100:2001 standard for High Voltage Switchgear and Control Equipment Part 100: High Voltage AC Circuit Breakers established by the International Electrotechnical Commission.

Per saperne di piùInvia richiesta
Interruttore di colonne ceramica SF6 ad alta tensione esterna

Interruttore di colonne ceramica SF6 ad alta tensione esterna

The 72.5KV Outdoor high-voltage SF6 ceramic column circuit breaker is designed for controlling and protecting 72.5KV transmission and transformation systems. It operates on a three-phase AC 50HZ outdoor high-voltage switchgear and can function and opener group. By utilizing the intelligent arc extinguishing principle of "thermal expansion+auxiliary blowing" and equipped with a CTB-1 operating mechanism, this circuit breaker meets the standards of GB1984-2003 and International Electrotechnical Commission standard IEC62271-100:2001 for High Voltage AC Circuit Breakers.

Per saperne di piùInvia richiesta
Interruttore di isolamento a due montanti con interruzione centrale da 36 KV

Interruttore di isolamento a due montanti con interruzione centrale da 36 KV

L'interruttore di isolamento a due post con interruzione centrale da 36 KV è realizzato in porcellana ad alta resistenza, che migliora la stabilità, l'affidabilità e la densità di resistenza del prodotto. Questa formulazione del materiale riduce al minimo la variazione di resistenza e aumenta la resistenza alla trazione del prodotto. Il layout strutturale prevede un margine di resistenza significativo, garantendo la stabilità operativa e l'affidabilità del prodotto.

Per saperne di piùInvia richiesta
Sezionatore a due montanti con interruzione verticale 12KV 1250AMP

Sezionatore a due montanti con interruzione verticale 12KV 1250AMP

The 12KV 1250AMP Vertical break two post isolating switch is specifically designed for use in 10(12,15,24)KV high voltage transmission and distribution lines. These switches serve the purpose of disconnecting and connecting single-phase or three-phase circuits without load and voltage. They are particularly engineered for single-phase application within a three-phase circuit system and are characterized by a simple and cost-effective design, ensuring ease of operation and maintenance. The switches are available in a range of rated current options, including 200400,600,630,800, and 1000,1250 amperes, providing the flexibility to select the most suitable option based on specific requirements. They are comprised of a base, pillar insulator, conductive part, and mechanism part.

Per saperne di piùInvia richiesta
Interruttore isolante a due montanti con interruzione verticale da 11 KV 2000 A

Interruttore isolante a due montanti con interruzione verticale da 11 KV 2000 A

The 11KV 2000amp Vertical break two post isolating switch is a composite-structured 12KV switch designed for outdoor line networks. Equipped with a CS-type operating mechanism, it effectively prevents incorrect operations, such as interlocking with live conductors and composite flash-locks. This negates the necessity for an additional earthline, providing a convenient and efficient solution. Furthermore, the pollution-proof isolating switch is particularly well-suited for use in heavily contaminated areas, effectively addressing shed pollution during operation and ensuring a clean and safe working environment.

Per saperne di piùInvia richiesta
Sezionatore di terra 145KV 3150A

Sezionatore di terra 145KV 3150A

145KV 3150A Earthing switch,The neutral point serves various functions, contributing to distinct technical characteristics and operational requirements. The BJ-type transformer neutral point gap grounding protection device plays a crucial role in preserving operational reliability, equipment insulation, and protective measures to ensure consistent performance.

Per saperne di piùInvia richiesta
126KV 1250A Sezionatore punto neutro

126KV 1250A Sezionatore punto neutro

126KV 1250A Neutral point disconneetor is specifically engineered for application in high-voltage transmission lines operating under no-load conditions. Its primary function is to provide electrical isolation during the maintenance of circuit breakers and other associated equipment, thereby ensuring compliance with insulation distance requirements and enhancing overall operational safety.

Per saperne di piùInvia richiesta
Sezionatore punto neutro 40,5KV 630A

Sezionatore punto neutro 40,5KV 630A

The The GW8 series neutral point disconnecting switch is an outdoor device designed for use with AC 50Hz and 60Hz. It is intended to connect the neutral point of a transformer under no load conditions. The switch can be easily operated using either the CJ motor operating mechanism or the CS8 manual operating mechanism. Comprising a monopole and an operating mechanism, the GW8 series ensures smooth and hassle-free operation. The monopole includes a base, post-insulator, conductive arm, contact, and other components. The operating mechanism, whether it's the CJ motor operating mechanism or the CS8 manual operating mechanism, is crucial to the disconnecting switch process. It drives the conductive arm through the connecting rod, enabling the opening and closing of the disconnecting switch. is an outdoor device designed for use with AC 50Hz and 60Hz. It is intended to connect the neutral point of a transformer under no load conditions. The switch can be easily operated using either the CJ motor operating mechanism or the CS8 manual operating mechanism. Comprising a monopole and an operating mechanism, the GW8 series ensures smooth and hassle-free operation. The monopole includes a base, post-insulator, conductive arm, contact, and other components. The operating mechanism, whether it's the CJ motor operating mechanism or the CS8 manual operating mechanism, is crucial to the disconnecting switch process. It drives the conductive arm through the connecting rod, enabling the opening and closing of the disconnecting switch.

Per saperne di piùInvia richiesta